MedQraft
← All insights
Medical devices

Developers Use It Easily, But Do New Users?

This article explores usability review questions considering users, usage environments, and device operations.
It connects observed behaviors from a hypothetical portable measuring device to design improvements and validation evidence.

Last regulatory review: 2026-09-21 Rev. 1.0 7 min read

There Are Unexplained Assumptions Even with Familiar Operations

Developers turn on the device, check its readiness, and naturally proceed with necessary operations.
If they have worked with the same prototype for a long time, they might know meanings that are not written on the screen.

But what about users encountering the device for the first time?

The fact that a developer successfully demonstrated the device does help in explaining its operation.
However, that alone makes it difficult to conclude that targeted users can safely use it under the same conditions.
Finding out what aspects of the developer's experience fill in the gaps is the starting point of this article.

This text is meant as a self-review question for medical device development teams.
It is not operational instructions for a specific device nor a substitute for product-specific usability evaluation plans.
The device mentioned in the examples is a hypothetical prototype for illustrative purposes.

Looking at Users, Environments, and Interfaces Together

The FDA’s Human Factors Considerations describe the interaction between the user, usage environment, and user interface.
This perspective examines user experiences, sensory and operational abilities, ambient light and noise, as well as device displays and controls.

The interface is not limited to the screen and includes all aspects where users interact with the product.
The FDA’s Applying Human Factors and Usability Engineering to Medical Devices was released on August 3, 2026.
This article references the scope and definitions from that guidance.

It is essential to distinguish between the guidance's recommendations and legal obligations and not apply U.S. materials directly as domestic approval requirements.

The questions and tables below have been created internally by MedQraft and are not direct translations of the original tables.
They summarize aspects of the overall procedure, testers, and passing criteria, and should not be used as is.

Examining "Who Writes" in Actual Roles

Can a single line stating "used by medical professionals" fully describe the usage scene? You can delve deeper into who the intended users are, their familiarity with the product, and the specific operations they undertake.

For instance, if one person prepares the device and another checks the results, you can ask how the information from the preparation stage is conveyed to the subsequent user.

Even among users with the same job title, those who use the product daily might have different expectations than those using it for the first time.
This is why merely knowing job titles does not allow for assumptions about experience.

In the review, distinguish between verified user information and the development team’s assumptions.
Any areas requiring actual user observation or interviews will remain verification tasks.
It is more useful to highlight what needs to be known rather than documenting unverified user behavior as definitive requirements.

Self-Review Questions Topics to Review
What role does the person have? Phases such as preparation, operation, and result verification
What are they familiar with? Distinction between experience with this product and similar products
What guidance are they receiving? Scope of instruction manuals and training actually provided
Where is it being used? Conditions of space and surrounding activities observed
What do they still not know? Unverified assumptions and additional questions to investigate

Hypothetical Case: Demonstrating Two States with One Light

Consider a hypothetical prototype of a portable measuring device.
When the power is on and measurement is ready, the same indicator light turns on.
The development team knows that internal preparation takes time and waits before proceeding.

Can a user encountering it for the first time interpret the light as indicating that preparation is complete? The review here is not simply whether the color of the light is appealing.
The critical question is how users interpret that indicator and how that interpretation influences their subsequent actions.

This case does not report a problem with a specific product.
The team can start by writing down the meaning they believe the indicator is trying to convey.
Then, they can observe what information the user sees to decide when to start acting.

Proposals like differentiating the indicator or changing the wording can become design candidates, but determining what is sufficient must be based on the product's context and verification results.
One should not conclude that changing the color arbitrarily resolved the issue.

Distinguishing Preferences from Actual Behaviors

"It was easy to use" may be a valid comment, but that alone does not reveal which steps were difficult.
If you pre-organize the behaviors you want to observe during internal exploration, the questions can become more specific.
For example, you could document points where users hesitated, a scene where they explained an indicator with a different meaning, or stages they needed help with from an instructor.

Separating the fact that users hesitated and the developer’s speculation about why is also crucial.
Before jumping to conclusions about the reasons, it is important to confirm what the user understood.

Observed Facts Example Common but Hasty Conclusion Questions to Confirm Next
Pausing during the preparation stage Because users are unfamiliar with it Was there sufficient information to guide the next action?
Describing the indicator as preparation complete Because they didn’t read the manual Does the indicator itself and actual instructions convey the same meaning?
Successful operation after guidance from an instructor They can use it alone What parts were performed independently and what parts required assistance?
Reduced hesitation in the modified prototype This solves the issue for all users Which user and under what conditions were these results verified?

The above table serves as an example to aid record-keeping and is not a test judgment table.
The criteria or conditions for determining success or failure should be independently established for actual purposes.

Linking Modifications to Reverification Questions

After concluding observations, connect the findings with design amendments.
Rather than simply writing "usability improvements," describe what was unclear, and how you intend to alter the information.

In the hypothetical indicator case, the goal might be to differentiate between power-on and preparation complete.
Keeping this aim recorded will clarify how you will verify the results of the changes later.

During the verification process, you can also review new questions that may arise to avoid confusion between different states.
It is useful to record observation conditions, versions of the prototypes used, and guidance provided.

Bundling results from different versions or explanation conditions makes it difficult to clarify why results differ.
In relation to this, you can also refer to the article discussing comparison conditions for performance test results.
While the purpose of the tests differs, the practical question remains that comparison conditions must be clarified.

Do Not Equate Internal Exploration with Final Verification

FDA guidance differentiates between formative evaluations that explore strengths, weaknesses, and unforeseen user errors during design and usability validation testing that evaluates user interaction effectiveness and risk control at later development stages.

You should not state that final verification has been completed simply because a developer demonstrated the device or received some feedback.
Efforts to organize questions and review prototypes internally can be utilized for preparing the next investigation and evaluation.

However, it must be clear how far the results can be interpreted.
This approach involves distinguishing between what was confirmed in the observations and what remains unconfirmed.

The actual target user, tasks, conditions, and methods for assessment must be planned according to the product's intended use and associated risks.
This article contains no information to determine test plans specific to products, so it does not present any specific personnel or evaluation methods as sufficiently adequate.

Five Questions to Bring to the Next Design Meeting

  • Can users determine their next actions without the development team’s explanation?
  • Have you validated the intended user roles and experiences in reality?
  • What are the conditions in the environments where the product will be used that have not been observed yet?
  • Have you documented the distinctions between observed facts and assumptions about the causes?
  • Are the modification objectives, verification results, and remaining questions interconnected?

In meetings, instead of trying to answer all questions immediately, you can choose one assumption that remains and designate it as a verification task for the next check.
If issues arise during this process that connect to the product's risk analysis, they lead to related reviews.
You can explore these perspectives further in the article discussing the connections of medical device risk management evidence.

Sources include the FDA’s publicly released guidance and definitions originally mentioned.
The guidance date is August 3, 2026, and the document verification date is September 21, 2026.
This text does not cover newly announced regulatory obligations and contains internally created hypothetical prototypes, tables, and questions by MedQraft.
It does not imply the suitability assessment of specific products or the provision of clinical services.

Let's talk

Apply what you have read
to your product.

Tell us your product's current stage and the questions you need to review.

Discuss your questions ↗
MedQraft / Let's talk

Project inquiry

Start with your challenge.
We will work through it together.

Tell us your product's current stage and the support you need.
We will review the questions and define a suitable scope of support.

Contact@medqraft.co.kr ↗
Information: name, company, email, inquiry and service of interest · Purpose: responding to your inquiry · Retention: until the inquiry is resolved Read the privacy policy
Privacy policy

MedQraft / Privacy

Privacy policy

MedQraft processes only the information needed for website inquiries.
We delete the collected inquiry information when the inquiry is resolved.

Effective date: September 18, 2026

1. Scope and purposes of processing

This policy applies to visits and business inquiries at www.medqraft.co.kr.
We process personal information to review and respond to inquiries, discuss the scope of support, and operate the website reliably.
Customer business data stored in Q-Atelier is governed by the relevant service agreement and separate notices.

2. Information collected and retention

Required information
Name, email address and inquiry
Optional information
Company, selected service of interest, and contact or business details you provide in your inquiry
Collection methods
Website inquiry forms and email inquiries
Basis for processing
Consent to collection and use provided through the inquiry form.
Where necessary to fulfill a request relating to the formation or performance of a contract, we process information on the applicable legal basis.
Retention period
We retain inquiry information until the inquiry is resolved, then delete it without delay.
If information becomes part of a separate contract, we separately explain the required information and retention period.
Where retention is legally required, only the relevant information is stored separately.

You may decline to provide required information, but this will prevent submission of the website inquiry form.
You can make an inquiry without providing optional information.
Do not submit sensitive information unnecessary for the inquiry, such as national identification numbers or patient information.

3. Service providers and external services

Inquiries are forwarded from the website server through an email delivery service to our company mailbox.
We do not maintain a separate inquiry database in this processing workflow.

Vercel Inc.
Website hosting, server-side inquiry processing, operations and security.
Technical information such as IP address, request time, browser and request details may be processed.
Plus Five Five, Inc. (Resend)
Delivery of inquiry notification emails containing name, email, company, service of interest and inquiry details, and management of delivery logs
Gabia Hiworks
Receipt, storage and replies to inquiries in our company mailbox

We do not sell inquiry information or provide it for advertising purposes.
We do not disclose it for an independent third party's purposes unless there is a lawful basis, such as a legal requirement or separate consent.

4. Overseas processing and storage

Overseas cloud services are used to process website requests and deliver emails.
Information entered in an inquiry is transmitted over an encrypted connection upon submission.

Vercel Inc. / United States
Information is transmitted for inquiry request processing and hosting.
Privacy contact: privacy@vercel.com.
Operational records are subject to the retention periods of the services and settings used and Vercel's processing policies.
Vercel data processing information
Plus Five Five, Inc. (Resend) / United States
Information is transmitted upon submission to deliver the inquiry email and manage delivery records.
Privacy contact: privacy@resend.com.
Resend's published default retention period for emails and logs on its standard plans is 30 days.
Earlier deletion may be requested from the provider.
Resend retention and deletion information

Deleting inquiry emails from our mailbox and deleting technical records held by external providers involve different processes.
You may contact the person listed below about deletion, restriction of processing or overseas processing.
If you do not wish to use overseas processing through the website form, you may email us directly.
The processing policies of the email services used will still apply.

5. Deletion and safeguards

After confirming that an inquiry has been resolved, we delete the email and separately saved copies.
Printed materials, if any, are destroyed by shredding or another method that prevents reuse.
Where deletion of information held by an external processor is necessary, we submit a request through that provider's deletion procedure.

Access to personal information is restricted to staff who need it for their work.
We protect information through HTTPS transmission and account access controls.
We do not publish materials containing personal information in public repositories or on public pages.

6. Your rights

You may request access, correction, deletion, restriction of processing or withdrawal of consent by contacting the designated email address.
We will verify your identity to the extent necessary, process the request under applicable law, and notify you of the result.
If we cannot fulfill a request, for example because of a legal retention obligation, we will explain the reason.
For requests made through a representative, we may verify their authority.

7. Access information and external content

We use Naver conversion tracking to measure visits and completed inquiries attributable to Naver search advertising.
Technical information such as the visited URL, referring page, browser and cookies, and whether an inquiry was completed, may be processed.
The name, email, company and inquiry text entered in the form are not included in conversion events.
You can block or delete cookies in your browser.

Server access information may be processed for website delivery and security.
Vercel Web Analytics is used for anonymous visitor statistics on the introduction page and Insights.
Insights statistics aggregate article views, referral sources, countries and device types.
Visitor analytics do not use analytics cookies.
Names, emails, companies and inquiry text from the consultation form are not included in analytics events.
Instagram-specific links use UTM parameters to identify referral sources.
Loading external video or fonts on the website may transmit technical information, including IP address and browser details, to the relevant provider.

You can block or delete cookies and site data in your browser settings.
Some features or external content may be restricted depending on your settings.

8. Privacy officer and contact

Business
MedQraft / Representative: Byeonghwi Kim
Privacy officer and inquiry contact
Byeonghwi Kim
Email
Contact@medqraft.co.kr
Postal inquiries
Suite 222, 56 Geumto-ro 80beon-gil, Sujeong-gu, Seongnam-si, Gyeonggi-do, Republic of Korea (Geumto-dong, Widen Tower)

For privacy-related complaints, you may contact the Personal Information Infringement Report Center or the Personal Information Dispute Mediation Committee for assistance.

9. Changes to this policy

Changes to processing purposes, information collected, retention periods or service providers will be published on this page with their effective date.

September 18, 2026: Website inquiry privacy policy first published

October 14, 2026: Added information on Insights visitor analytics and Instagram referral measurement